EFFECT UNBALANCE VOLTAGE IN MOTOR
Voltage Unbalance - A motor that gets an unbalanced
power supply will cause an imbalance of the current flowing to the motor stator
winding. Even though the percentage of voltage imbalance is small (Percent
Voltage Unbalance), it can cause a large percentage of the imbalance current
flowing into the motor stator winding, so that it can increase the temperature
rise of the motor which in turn can cause disturbances to the motor. It is
better if the input voltage to the motorbike must be evenly distributed, if the
voltage is not balanced (Voltage Unbalance), this will also cause a decrease in
motor power which is proportional to the percentage of supply voltage
imbalance, such as a graph of the effect of voltage umbalance (unbalanced
voltage) on the decrease in motor power below. this:
To calculate the percentage of unbalanced voltage (Percent Voltage
Unbalance) you can use the following formula:
Percent Unbalance = 100 x Max. Volt Deviation From Average Volt. / Average Volt.
Example of Percent Unbalance Voltage:
For example, if a three-phase motor with a power of 100 kW operates with
input voltages of 380, 372 and 395, the Percent Unbalance of the motor input
voltage is:
applied to the running motor terminals:
➤ Average Voltage = (380 + 372 +
395) / 3
➤Average Voltage = 382 V
➤ Max. Voltage Deviation = 15 V
➤ Percent Unalance = 100 x 15/382
➤Percent Unalance = 3.9%
When viewed from the graph: Percent Voltage Unbalance at the point of 3.9%, it will make the Derating Factor around 0.84 which means about 84 kW against the Rated Power Motor 100 kW. This indicates that with a Percent Unbalance of around 4%, a 100 kW motor can only be charged around 84 kW to prevent damage to the motor.
Important notes from the chart above:
Do not operate the motor with the Unbalance Voltage Percentage above 5%
Besides the motor experiencing power derating, the
voltage unbalance (Voltage Unbalance) will also produce an effect that affects
the performance characteristics of the motor, as follows:
Torque Characteristics: Unbalanced voltage will reduce
the motor rotor lock value and the motor torque
Characteristics of Full-Load Speed: Unbalanced voltage
will result in a slight decrease in the Full-Load - Speed parameter of the
motor.
Motor Current: Unbalanced Voltage (Voltage Unbalance will
increase the imbalance 6 to 10 times at full load current).
Temperature: From the results of research and experience
in the field, the percentage of unbalanced voltage (Percent Voltage Unbalance)
up to 3.5% will cause the motor temperature to rise by 25%.
Comments